06 D U R A TIO N O F K E TTU P A T TH E S E A M E N D

D uration ofthe kettup function atthe seam end.
S w itch offto save energy.

07 TH R E A D LIFTIN G A T TH E S E A M E N D

The num berofstitches untilthe needle thread is released atthe seam
end.

08 FZ B LO C K IN G TIM E A T TH E E N D

Tim e delay forfeeding a new w orkpiece (blocking tim e afterlight
barrierunblocked).

09 P H O TO C E LL 15 O N /O FF

S w itching status ofphotocellF15 only available w ith optionalfusing
station.
01 = Function on
00 = Function off
Ifno lightbarrieris m ounted,an errorm essage appears.

10 S TA C K E R -> E JE C TO R D O W N

The tim e the ejectoris low ered and fixes the w orkpiece untilitis taken
overby the stacker.

11 C O N TO U R S C A N N IN G TIM E

R esponse tim e foraltering the pullerspeed (photocell16)

12 TH R E A D M O N ITO R S E N S ITIV ITY

S etting ofthe thread m onitor
00 = Function off
01 = H igh sensitivity
99 = Low sensitivity

(the setting depends on the sew ing thread used)

13 E FK A P O S ITIO N U P

N eedle position dow n atthe sew ing start,needle position up w hen
threading.