Donut Robot Mark II-Gas TS

THE PILOT WILL NOT IGNITE, AND THE CONVEYOR WILL NOT RUN.

Possible Causes

What To Do

The power cord is not plugged in, or the outlet
has no power.

Connect the machine to a good power source.

The gas is not turned on or the connection to gas
source is loose.

Turn on gas. Reconnect to gas source.

WARNING

To avoid being burned, electrocuted, or otherwise
injured, before doing any of the following, turn off
the machine, allow the shortening to cool, and
disconnect the machine from the power source.

The power cord is defective.

Replace the power cord.

The ignite sensor is dirty or broken

Clean sensor and tighten if necessary or replace
sensor if broken.

The system safety lockouts.

Please follow these steps:

1. Close the first main valve.

2. Close the first main pilot valve gas control.

3. Set the fryer thermostat below 200

°F/93°C.

4. Move the on/off switch to OFF.

5. Wait at least five minutes before trying again

to light the pilot.

WARNING

Failure to wait at least five minutes for gas to
dissipate could result in a fire or an explosion
when the pilot is lit again.