Comtech EF Data DMD1050 User Manual

Page 113

Advertising
background image

DMD1050 Satellite Modem Board

Web Browser

MN-DMD1050

7–19

Revision 9

Transmit / AUPC Menu

Figure 7-12. Transmit / AUPC Menu

LOCAL AUPC (menu)

The 'LOCAL AUPC CONFIGURATION' Menu contains the
local configuration parameters for the AUPC Function.


AUPC MODE

{DISABLED, NEARSIDE, RADYNE, EFDATA}

DISABLED: Allows the user to enable or disable the Local
AUPC Function of the local modem.

EFDATA: Enables EFDATA Local AUPC Function. In the
event that the remote or local demodulator losses lock, the output
power level will adjust itself to the level settings indicated in the
'REMOTE CL ACTION' Menu or the 'LOCAL CL ACTION'.

RADYNE: Enables Radyne Local AUPC Function. In the
event the remote demodulator losses lock, the local output power
level will adjust itself to the nominal level. This nominal power
should be set to a level high enough to re-establish
communications regardless of rain fade.

NEARSIDE: Enables NEARSIDE Local AUPC function. In
the event the local demodulator losses lock due to signal loss, the
output power level will adjust itself to the nominal level. This
nominal power should be set to a level high enough to re-
establish communications regardless of rain fade.


NOMINAL TX POWER

{0 TO -25 dB}

This allows the user to set the nominal Transmit Power. The
nominal transmit power is the default output power level.

MINIMUM TX POWER

{0 to -25 dB}

This allows the user to set the minimum Transmit Power.

Advertising