Appendix D. Web Browser

Setup Guide

D.1

Introduction

This section provides quick setup instructions to access the Web Browser through the RJ45
Ethernet interface. The Web user interface allows for complete monitoring and control of all
modem parameters and functions via a 10BaseT Ethernet connection. For more details on the
various WEB configurations and a description of all the available selections, please refer to the
manuals.

D.2

Required Items

Modem

RJ45 to RJ45 crossover cable

Computer

Default Plug/Jumper if needed for (JP5 & JP6)

D.3

Web Interface Setup Guidelines

D.3.1 Preparing the DMD1050 for Web Setup

The unit is shipped from the factory with the IP addresses pre-configured to an accessible IP
address known as IP TEST MODE (see below). If user has difficulty accessing the Web Browser
interface, then it is recommended that the user install the Default Jumper/Plug that will change
the IP addresses to an accessible address. To reset IP addresses, user must install the Default
Plug between pins 1 & 2 on JP5 and JP6. Jumpers are supplied in the connector kit. This will
change the IP network setting that the user can access.

1. Turn off power to the DMD1050.

2. Install the Reset jumper between pins 1 & 2 of JP5 and JP6 connector. Refer to figure 4-5 for

jumper location.