Revision 9
Sweep Delay (sec):
{0.0 – 900.0 sec}
Allows the user to set the reacquisition delay time in 1/10
th
second increments.
Reacquisition Range (Hz):
{0 – 32000 Hz}
Allows the user to set the reacquisition sweep in 1 Hz
increments.
Adj Carrier Pwr:
{Normal, Suppressed}
Allows the user to indicate adjacent carrier as Normal or
Suppressed (High Power). Unit will increase or decrease post
dissemination gain appropriately.
Fast Acquisition:
{DISABLED, ENABLED}
Allows the user to disable or enable the Rx fast acquisition
capability.
Carrier Input Level Limit:
{-30 to 90 dBm}
Allows the user to adjust the low level threshold limit for input
power. Input power level below the threshold limit will trigger a
major alarm on the demodulator.
EB/NO Alarm Thrsh
{0.0 to 9.90 dB}
Allows the user to set the desired E
b
/N
o
for the local receiver.
This setting is compared against the receive E
b
/N
o
and
commands to the remote modem to increase or decrease
Transmit Power accordingly are sent.