Comtech EF Data DMD1050 User Manual

Page 50

Advertising
background image

DMD1050 Satellite Modem Board

Theory of Operation

MN-DMD1050

3–24

Revision 9

Table 3-2. Local AUPC Functions

Function

AUPC Available Options

Description

AUPC MODE

DISABLE, NEARSIDE, RADYNE,

EFDATA

Enables/Disables the AUPC to function

locally

NOMINAL POWER

0 TO -25 dB

Sets default output power to be used

MINIMUM POWER

0 TO -25 dB

Sets minimum output power to be used

MAXIMIM POWER

0 TO -25 dB

Sets maximum output power to be

TARGET Eb/No

4.0 TO 16 dB

Desired E

b

/N

0

of remote modem

TRACKING RATE

6.0 to 0.5 dB/MIN

Adjustable in .5dB increments

LOCAL CL ACTION

HOLD, MAXIMUM, NOMINAL

Allows user to determine what power

setting the remote modem will use in the

event of a carrier loss at the local side.

REMOTE CL ACTION

HOLD, MAXIMUM, NOMINAL

This setting allows users to determine

what local output power setting to use in

the event that the remote end has a

carrier loss.

1. The AUPC Menus are located under the Modulator Menu as shown in Section 4.

2. The EF AUPC Menu displays when EFAUPC Framing is enabled in the Demod and Mod set up menus.

3. Highlighted areas are activated when modem is set to EF AUPC


Table 3-3. Remote AUPC Functions (EF AUPC Only)

Function

AUPC Available Options

Description

AUPC MODE

Disable, EFDATA

Enables/Disables the AUPC to function

remotely

LOOPBACK

Enabled/Disabled

Loop back test over satellite link

TX 2047 TEST BER

Enabled/Disabled

Initiates 2047 Test pattern BER Test

RX 2047 BER

Status Menu

Identifies the BER status on the distant RX

side

AUPC DEF LVL

Sets default output power to be used

The Remote AUPC Menus are only supported by EFAUPC