Comtech EF Data DMD1050 User Manual

Page 75

Advertising
background image

DMD1050 Satellite Modem Board

Maintenance and Troubleshooting

MN-DMD1050

5–3

Revision 9

5.2.1.4 Minor Rx Alarms

Alarm

Possible Cause

BUFF UNDERFLOW

Shows that a Doppler Buffer underflow has occurred.

BUFF NEAR EMPTY

Shows that the Doppler Buffer is about to underflow.

BUFF NEAR FULL

Shows that the Doppler Buffer is about to overflow.

BUFF OVERFLOW

Shows that a Doppler Buffer overflow has occurred.

RX DATA ACTIVITY

Shows that there is no Rx Data activity. For the Ethernet Interface, Shows that no

Ethernet port is active (no cable is plugged in).

SAT AIS

Shows that AIS has been detected in the receive satellite data stream.

IFEC LOCK

Shows that the Inner Codec is not locked.

OFEC LOCK

Shows that the Reed-Solomon Decoder is not locked.

INTERLEAVER

Shows that the Reed-Solomon Interleaver is not synchronized.

EBNO (dB)

Shows that the Eb/No is outside of limits.

IBS BER

Shows that there are more than one in 1000 bits in error in IBS mode.

RX DVB FRAME LOCK Shows that the Rx Satellite Data Stream Framing is not DVB.

5.2.1.5 Common Major Alarms

Alarm

Possible Cause

TERR FPGA CFG

Shows an Interface Card FPGA configuration failure probably caused by a missing, or

wrong file.

CODEC FPGA CFG

Shows Turbo Codec Card FPGA configuration failure probably caused by a missing, or

wrong file.

+1.5V RX SUPPLY

Shows the measured voltage of the 1.5 Volt Rx power bus located inside the modem.

+1.5V TX SUPPLY

Shows the measured voltage of the 1.5 Volt Tx power bus located inside the modem.

+3.3V SUPPLY

Shows the measured voltage of the +3.3 Volt power bus located inside the modem.

+5V SUPPLY

Shows the measured voltage of the +5 Volt power bus located inside the modem.

+12V SUPPLY

Shows the measured voltage of the +12 Volt power bus located inside the modem.

+24V SUPPLY

Shows the measured voltage of the +24 Volt power bus located inside the modem.

EXT CLOCK ACT

Shows that the External Clock is not active.

EXT REF ACT

Shows no activity on the External Reference.

EXT REF LOCK

Shows that the External Reference PLL is not locked.

5.2.2 Alarm Masks

The DMD1050 performs a high degree of self-monitoring and fault isolation. The alarms for
these faults are separated into the following three categories: