Comtech EF Data SDM-300L3 User Manual
Page 253

SDM-300L3 Satellite Modem
Revision 1
Fault Isolation
MN/SDM300L3.IOM
9–5
Test Note
Fault/Alarm Relay
Test Points Connector/Pins
1
TX FAULT
Pin 4 (NO), 5 (COM), 6 (NC) ****
2
RX FAULT
Pin 7 (NO), 8 (COM), 9 (NC) ****
3
COM EQ FAULT
Pin 1 (NO), 2 (COM), 3 (NC) ****
4
TX ALARM #2
Pin 4 (NO), 5 (COM), 6 (NC) +
5
RX ALARM #3
Pin 7 (NO), 8 (COM), 9 (NC) +
6
PRIMARY ALARM
Pin 43 (NO), 10 (COM), 27 (NC) +
7
SECONDARY ALARM
Pin 44 (NO), 11 (COM), 28 (NC) +
8
DEF MAINT ALARM
Pin 17 *****
* IDR
only.
** IBS
only.
*** D&I
only.
****
A connection between the common and N.C. contacts indicate fault.
*****
Signal is open collector high impedance if faulted.
+
A connection between the common and N.O. contacts indicate alarm.
Figure 9-1. SDM-300L3 Fault Tree (Continued)