Comtech EF Data SDM-300L3 User Manual
Page 369

SDM-300L3 Satellite Modem
Revision 1
Remote Control Operation
MN/SDM300L3.IOM
A–17
A.3.6
MUX PCB Configuration Commands (MUX PCB Installed Only)
Mux
Tributary
Data Rate &
Enable
Command:
Response:
Status:
Response:
<add/MTDR_x_yyyyyy'cr'
>add/MTDR_x_yyyyyy'cr''lf']
<add/MTDR_x'cr'
>add/MTDR_x_yyyyyy'cr''lf']
Where:
x = 1 to 8 (tributary number).
yyyyyy = OFF (disabled), or 0.6 to 4000.0 (kbps in
100 bits steps).
Mux
Tributary
Interface
Type
Command:
Response:
Status:
Response:
<add/MTIT_x_yyyyy'cr'
>add/MTIT_x_yyyyy'cr''lf']
<add/MTIT_x'cr'
>add/MTIT_x_yyyyy'cr''lf']
Where:
x = 1 to 8 (tributary number).
yyyyy = RS422 or RS232.
Mux
Tributary
Clock
Phase
Command:
Response:
Status:
Response:
<add/MTCP_x_yyy'cr'
>add/MTCP_x_yyy'cr''lf']
<add/MTCP_x'cr'
>add/MTCP_x_yyy'cr''lf']
Where:
x = 1 to 8 (tributary number).
yyy = NRM (normal clock phasing), INV (inverted clock
phasing).
Mux
Tributary
Data Phase
Command:
Response:
Status:
Response:
<add/MTDP_x_yyy'cr'
>add/MTDP_x_yyy'cr''lf']
<add/MTDP_x'cr'
>add/MTDP_x_yyy'cr''lf']
Where:
x = 1 to 8 (tributary number).
yyy = NRM (normal data phasing), INV (inverted data
phasing).
Mux
Tributary
Mode
Command:
Response:
Status:
Response:
<add/MTMD_x_yyyyy'cr'
>add/MTMD_x_yyyyy'cr''lf']
<add/MTMD_x'cr'
>add/MTMD_x_yyyyy'cr''lf']
Where:
x = 1 to 8 (tributary number).
yyyyy = SYNC or ASYNC.
Mux
Tributary
Async
Format
Command:
Response:
Status:
Response:
<add/MTAF_x_yyy'cr'
>add/MTAF_x_yyy'cr''lf']
<add/MTAF_x'cr'
>add/MTAF_x_yyy'cr''lf']
Where:
x = 1 to 8 (tributary number).
yyy = 7E1, 7O1, 7N2, 7E2, 7O2, 8N1, or 8N2.