6.10.2.1 Cartridge mechanical seals

Sleeve design 1 and 2
Review the seal assembly instructions and drawings
provided by the seal manufacturer.
a) If the pump is equipped with a sleeve [2400], slip it

into place over the impeller end of the shaft [2100].

b) Install a nose cone on the end of the shaft and

then slide the cartridge seal [4200] onto the shaft
until it lightly touches the bearing housing [3200]
or adapter [1340].

c) Install the rear cover plate [1220] to the bearing

housing (Group A and 1) or the bearing housing
adapter (Group B, C and 2) by using the cap
screws [6570.2].

d) Install the cartridge seal gland to the rear cover

plate [1220] using studs [6572.2] and nuts [6580.2].

e) Install the impeller [2200] as instructed in section 6.7.
f) Tighten set screws on the seal to lock the rotating

unit to the shaft. Finally, remove centering clips
from the seal.


Sleeve design 3
Review the seal assembly instructions and drawings
provided by the seal manufacturer.
a) Loosely attach the cartridge seal gland to the rear

cover plate [1220] using studs [6572.2] and nuts
[6580.2].

b) Install the rear cover plate [1220] to the bearing

housing (Group 1) or the bearing housing adapter
(Group 2) by using the cap screws [6570.2].

c) Install new tolerance rings into each end of the

sleeve [2400]. (See Figure 6-22.)

Figure 6-22

d) Install sleeve assembly onto shaft [2100] utilizing

the nose cone to ensure the end of the sleeve
remains flush with the end of the shaft. (See
Figure 23.)

Figure 6-23

e) Install O-ring onto flange portion of the sleeve.

(See Figure 6-24.)

Figure 6-24

f)

Install the impeller [2200] as instructed in section 6.7.

g) Tighten the nuts [6580.2] used to attach the

gland to the cover plate [1220].

h) Tighten set screws on the seal to lock the rotating

unit to the shaft. Finally, remove centering clips
from the seal.


6.10.2.2 Component type mechanical seal -
sleeve design 1 and 2
Review the seal assembly instructions and drawings
(seal set dimension) provided by the seal manufacturer.
In order to properly set a component seal it is necessary
to first locate the shaft in its final axial position. This is
accomplished in the following manner:
a) Install the rear cover plate [1220] to the bearing

housing (Group A and 1) or the bearing housing
adapter (Group B, C and 2) by using the cap
screws [6570.2].

b) Install and set the impeller [2200] clearance as

outlined in section 6.6. Put bluing on the shaft/
sleeve in the area near the face of the seal
chamber [rear cover 1220]. Scribe a mark on the
shaft at the face of the seal chamber. (Figure 6-25.)

c) Remove the impeller and seal chamber (rear cover)

following the instructions given in section 6.8 and
install a nose cone onto the end of the shaft.

Figure 6-25

Single internal seal installation
d) Place the gland [4120], gland gasket [4590.3],

stationary seat and a second gland gasket
[4590.3] onto the shaft until it lightly touches the
bearing housing (Group A and 1) or adapter
(Group B, C and 2).