Hydraulic/Mechanical Components
Meters
Replacing O-rings (Body and Cover Leaks)
Note: Always use Gasboy-approved O-rings and gaskets.
Replace the following O-rings for obvious leaks or during “off unit” repair:
• Inlet/Discharge Flange O-ring
• Body/Cover O-ring
• Valve Seal O-ring
• Lower Bearing Housing O-ring
To replace the O-rings, proceed as follows:
1
Follow steps
.
2
Remove the body cover and lower bearing housing.
3
Remove the O-ring(s) and install a new one(s). Lubricate the O-ring(s) with silicone grease.
Ensure that the O-ring is in the groove before tightening the cover(s).
4
Install the cover(s). Torque all meter bolts.
5
Follow the steps in
.
Figure 6-15: Replacing O-rings
Inlet/Discharge Flange O-ring
Body Cover O-ring
Lower Bearing Housing O-ring
1
2
4
5
3
6