OPERATING SEQUENCE
OPERATING INSTRUCTIONS
1.
Insert key in assigned lock, turn 180
°
.
2.
Remove nozzle from holder.
3.
Move start lever down over nozzle holder to reset register to zero and start pump. If your
system is equipped with the Start Delay feature, there may be a delay of several seconds
until delivery begins. Dispense product.
4.
After delivery, return start lever to original upright OFF position.
5.
Replace nozzle in holder.
6.
Turn key off and remove. Close door.
Please notify your fuel or equipment distributor of any malfunction.
MANAGER INSTRUCTIONS FOR BYPASSING ELECTRIC KEYTROL
In case of difficulties, Electric Keytrol may be bypassed as follows:
1.
After removing power, open door, insert bezel key and turn clockwise 1/2 turn.
2.
Lift up and outward until the bezel clears the bottom of the enclosure. Then, pull downwards
until the bezel is clear. Set the bezel aside on a clean, level surface.
3.
Move AUTO/MAN switch down to the MAN or manual position.
4. Replace bezel, being careful not to damage the relay, and turn bezel key 1/2 turn
counterclockwise to remove.
5.
Restore power and operate pump manually until the Electrical Keytrol can be serviced.
6.
If the pump still will not operate, either the dispenser is at fault or power is off.