Gasboy CFN III Mgnr's Mnl V3.4 User Manual
Page 129

MDE-4315 CFN Series CFN III Manager’s Manual for Windows NT · August 2004
Page 113
Attendant Cards
Proprietary Cards
3
In a CFN w/Key Option system, if you use a code key with PIN loaded in the Lookup Table,
verification will be done by the Site Controller (see
for more
information).
4
The following Key data will not be used on the CFN Key Option system. and their values will
be ignored:
• Previous Odometer (old location)
• Last Odometer (old location)
• Vehicle Class
• Maintenance A Odom
• Maintenance A Date
• Maintenance B Odom
• Maintenance B Date
• Maintenance C Odom
• Maintenance C Date
5
CFN w/Key Option system single, dual and supervisor key limitation codes, authorization
codes, price level and restriction codes are restricted as follows:
• Cannot be omitted.
• Digits must be set to one for each.
• Offsets at the Site Controller must be set to the following:
Limitation code = 0
Authorization code = 1
Price Level = 2
Restrictions = 3
• Dollar amount restriction code is not available.
6
CFN w/Key Option system single, dual, supervisor, dipstick and delivery key Expiration
Dates are restricted as follows:
• Cannot be omitted.
• Digits must be set to four.
7
CFN w/Key Option system allows a Key/Card combination for dual cards with the following
restrictions:
• The key/card combinations is limited to a vehicle key and an employee card.
• The check digit on the vehicle key cannot include a pin check.
• If the check digit on the employee card includes a pin check, the pin verification is done
by the Site controller.
8
CFN w/Fleekey system Key ID characters can only be numbers, field separators and
Supervisor characters. The Key Option system allows them to be alpha characters, as well.
9
CFN w/Key Option system account number on a key is 1 to 19 of the 20 key ID characters.
10
CFN w/Key Option keys may not be compatible with 1000 FleetKey/TopKAT keys. They may
be if encoded under the 1000 Fleetkey/TopKAT mode and no PIN.
11
The CFN w/Key Option system does not use key numbers.The KE200 Key Encoder in the
CFN mode sets key numbers to a default value of 9999.
12
The Key Option Manager Plus will not be compatible with the CFN w/Key Option system.