Cmd_set_ahrc_param, Mca527 – GBS Elektronik MCA-527 Firmware Commands User Manual

Page 22

Advertising
background image

MCA527

Command name

CMD_SET_AHRC_PARAM

Compatibility

New MCA527 command (since firmware version 14.00).

Execution right

Necessary

Description

The command allows to set the AHRC parameters.
param: parameter to be set
-1

= AHRC trigger threshold (allowed range = 0 … 65535

22

)

0 … 9

= AHRC [0 … 9] group width (allowed range = 1 …2147483647

22

)

value:

new value corresponding to the allowed range

The command is ignored and responds with an error value if a measurement is still running.

Format

integer

integer

integer

long

integer

Parameter

preamble

command

param

value

end flag

Byte string (HEX)

A5

5A

2D

01

p

l

p

h

value

l

...

...

value

h

B9

9B

22 The given intervals for the parameters only prevent a firmware hangup. They do not guarantee a meaningful result.