Note:

–  Select the firing parameters on the basis of the furnace.
–  A maximum of 6 units (e.g. 6 single crowns or two 3-unit bridges) may be fired simultaneously.

Glass-ceramic

Fusion

Pr

ocess

Do not place the restoration at the periphery of the IPS e.max CAD Crystallization Tray.

Place the restoration including the pins into the centre of the IPS e.max CAD Crystallization Tray.

Furnace

P300

Pre-

drying

(software 5.1

or higher)

B

[°C/°F]

403/757

S

[min]

02:00  

t

1

[°C/°F/min]

30/54

T

1

[°C/°F]

820/1508

H

1

[min]

02:00  

t

2

[°C/°F/min]

30/54

T

2

[°C/°F]

840/1544

H

2

[min]

07:00

V1

1

/

V1

2

[°C/°F]

550/820

1022/1508

V2

1

/

V2

2

[°C/°F]

820/840

1508/1544

L

[°C/°F]

600/1112

t

l

[°C/°F/min]

0

Furnace

P500

P700

EP 5000

[°C/°F]

403/757

[min]

6:00

B

[°C/°F]

403/757

S

[min]

02:00  

t

1

[°C/°F/min]

30/54

T

1

[°C/°F]

820/1508

°F

[min]

02:00  

t

2

[°C/°F/min]

30/54

T

2

[°C/°F]

840/1544

H

2

[min]

07:00

V1

1

/

V1

2

[°C/°F]

550/820

1022/1508

  

V2

1

/

V2

2

[°C/°F]

820/840

1508/1544

L

[°C/°F]

600/1112

t

l

[°C/°F/min]

0

Programat P500, P700, EP 5000
Firing parameters:  IPS e.max CAD-on technique Fusion/Crystallization firing  

Programat P300
Firing parameters:  IPS e.max CAD-on technique Fusion/Crystallization firing

Use the pre-drying function for this firing cycle. For pre-drying, set the furnace head position to 100%.

Notes on cooling after completion of the firing program
In order to ensure "smooth" cooling of the restoration after firing, please observe the following notes:
–  Wait for the acoustic signal or optical indication of the furnace at the end of the firing cycle before the firing tray with 

the fired objects is removed.

–  Do not touch the hot objects with metal tongs. 
–  Allow the objects to cool to room temperature in a place protected from draft.