background image

20

5.4 Adjustable parameters and possible value ranges

Symbol Parameter

Value range °C

Value range °F

P

Program number

1-300

B

Stand-by temperature

100-700 °C

212-1292 °F

S

Closing time (min : sec)

00:18-30:00

t

Temperature increase rate

10-140 °C/min

18-252 °F/min

T

Holding temperature

100-1200 °C

212-2192 °F

H

Holding time (min : sec)

00.01-60:00

V1

Vacuum on

0 or 1-1200 °C

0 or 34-2192 °F

V2

Vacuum off

0 or 1-1200 °C

0 or 34-2192 °F

L

Long-term cooling

0 or 50-1200 °C

0 or 122-2192 °F

tL

Cooling temperature rate

0 or 1-50 °C

0 or 2-90 °F/min

t

Temperature increase rate 2

nd

stage 10-140 °C/min

18-252 °F/min

T2

Holding temperature 2

nd

stage

100-1200 °C/min

212-2192 °F

H2

Holding time 2

nd

stage (min : sec)

00.01-60:00

V1 2

Vacuum on temp. 2

nd

stage

0 or 1-1200 °C

0 or 34-2192 °F

V2 2

Vacuum off temp. 2

nd

stage

0 or 1-1200 °C

0 or 34-2192 °F

Automatic plausibility check
The furnace is equipped with an automatic plausibility check function. The parameters
(e.g. T 960 but L 1000) are checked upon each program start.
In case of contradictory parameter combinations, the program stops automatically and
the respective error number is indicated.

5.3 Program structure

5.3.1 Firing programs
All the firing programs are equivalent and,
therefore, full-fledged programs. In each program,
all the parameters can be adjusted.

a) Ivoclar Vivadent firing programs for Ivoclar

Vivadent materials

When the furnace is delivered ex works, the

Ivoclar Vivadent firing programs already contain
the recommended material parameter settings.
Moreover, the programs are write-protected.
Consequently, it is not possible to accidentally
overwrite the parameters.

Please refer to the respective program table (list

of parameters) in Chapter 10.

However, the parameters are designed in such

a way that they can be changed and over-
written at any time, if the programs are to be
used for other purposes. Therefore, these
programs are also available as free, individual
programs.

b) Individual firing programs
The individual firing programs (at least 300) can

be programmed freely.

5.3.2 Press programs
a) Ivoclar Vivadent press programs for Ivoclar

Vivadent materials

When the furnace is delivered ex works, the

standard press programs already contain the
recommended material parameter settings.
They cannot be adjusted.

b) Individual press programs
The individual press programs (20) can be

programmed freely.