9. Product Specifications

9.1 Delivery form

– Programat EP 3000/G2
– Programat fring tray Kit
– Firing plate
– Automatic Temperatur Checking Set 2 ATK 2 (Test Set)
– USB download cable
– USB Stick Programat
– PrograBase 2 Software
– Service passport equipment
– Operating Instructions
– Cooling grid

9.1.2 Recommended accessories
– Programat Accessories Set
– Automatic Temperature Checking Set 2 (ATK 2)
– Vacuum pump VP4

9.2 Technical data

Power supply

110–120 V / 50–60 Hz

200–240 V / 50–60 Hz

Overvoltage category II
Contamination level 2

Tolerated voltage fluctuations

+/- 10%

Max. power consumption

12 A at 110-120 V

8.5 A at 200-240 V


Acceptable data for vacuum pumps from other manufacturers
Max. output:

250 W / max. leakage current 0.75 mA

Final vacuum:

< 50 mbar

Use only tested pumps

Electrical fuses:

110–120 V:

250 V / T 15 A (heating circuit)

250 V / T 5 A (vacuum pump)


200–240 V:

250 V / T 8 A (heating circuit)

250 V / T 3.15 A (vacuum pump)

Dimensions of electrical fuses:

110–120 V:

Diameter 6.3 x 32 mm

200–240 V:

Diameter 5 x 20 mm

Dimensions of the closed furnace:

Depth: 430 mm / Width: 305 mm / 410 mm (with cooling tray)

Height: 565 mm

Usable size of the firing chamber:

Diameter 80 mm

Height 48 mm

Max. firing temperature:

1200 °C

Weight:

Furnace base: 12.0 kg

Furnace head: 7.0 kg

Safety information
The Programat EP 3000/G2 complies with the following guidelines:
– EN61010-1:2001 2

nd

Ed.

– IEC61010-1:2001 2

nd

Ed.

– UL/CSA61010-1:2004 2

nd

Ed.

– EN61010-2-010:2003 2

nd

Ed.

– IEC61010-2-010:2003 2

nd

Ed.

– CSA61010-2-010:2004 2

nd

Ed

Radio protection / electromagnetic compatibility

EMC tested

9.3 Acceptable operating conditions

Acceptable ambient temperature range:
+5 °C to +40 °C / +41 °F to +104 °F
Acceptable humidity range:
80% maximum relative humidity for temperatures up to 31 °C
(87.8 °F) gradually decreasing to 50% relative humidity at 40°C
(104 °F); condensation excluded.
Acceptable ambient pressure:
The furnace has been tested for use at altitudes of up to 2,000 m
(6562 ft.) above sea level.

9.4 Acceptable transportation and storage conditions

Acceptable temperature range: -20 °C to +65 °C / -4 °F to +149 °F
Acceptable humidity range:

Max. 80% relative humidity

Acceptable ambient pressure:

500 mbar to 1060 mbar

Use only the original packaging of the Programat EP 3000/
G2 together with the corresponding foam material for shipping
purposes.