5. Operation and Configuration

5.1 Introduction to the operation

The Programat EP 5000/G2 is equipped with a colour graphical
display with backlighting. The furnace can be operated by means of
the keypad or touch screen.
The numeric and command keys can be used to program and
control the furnace.

5.2 Explanation of the key functions

START (Start LED)

Starts the selected program. The fact that a

program is running is indicated by the green LED.

If the program is interrupted (1 x STOP), the Start

LED flashes until renewed pressing of START

results in the program being resumed.

ESC

Ends an entry without accepting the value.

Return from the current to the previous menu.

Confirmation of error messages.

Enter

Confirmation of entered value.

Numeric keypad, 1–9 and 0

Used to enter numeric values.

Touch Screen

The display is touch-sensitive. Slightly tapping it

with the fingertip will result in the desired button

being marked with a thick, black frame. After

that, the corresponding function is immediately

executed (e.g. the display changes) or the touch

button is now ready for an entry by means of the

numeric keypad or the +/- keys.

Pressing or firing

Choice between the firing and press mode

Power-saving key (89)

Power-saving function activated (only possible
with the furnace head closed and the furnace on
idle). The display shows the power-saving icon.
Pressing any key ends the power-saving
function.

The energy saving mode (Power Saving

Technology) is available in the
EP 5000/G2 only in the firing mode.
In the press mode, the energy saving
function is disabled, as the furnace must
fulfil additional requirements.

Key

Function

Program key

Shows the currently selected program. Pressing

the key several times: graphical representation of

the program and table-type view with details

Up, down

In the parameter list (pressing P two times), these

keys can be used to move the cursor.

Minus, Plus, or changing pages

These keys can be used to change the numeric

values.

Changing between different pages if a view

consists of several pages.

Settings (selection)

Go to the settings menu for: settings, information,
special programs, and calibration.

Help

Go to the help feature for the current screen.

Home

Return to „Program Group Indication“

(main menu)

Open furnace head

Opening of the furnace head in 5 seconds.

Close furnace head

Closing of the furnace head in 5 seconds.

STOP

A program in progress can be interrupted by

pressing STOP once. Pressing STOP twice will

abort the program.

Movement of the furnace head can be stopped

at any time by pressing STOP.

The beeper can be confirmed by pressing STOP.