5 settings and information – Ivoclar Vivadent EP5000-G2 User Manual

Page 21

Advertising
background image

21

5.5 Settings and information

By pressing the „cogwheel“ key,
you will reach the „Selection“
screen. The desired screen is
displayed by pressing the
corresponding touch button.

5.5.1 Settings

The desired group of settings is
displayed by pressing the
corresponding touch button. The
– / + keys can be used to
navigate within these two pages.
The desired parameter field is
activated by tapping the
respective touch button and the
settings can be edited using the
„“-“/“+“ keys.

e.g. Speaker
Pressing the corresponding touch
button activates the respective
parameter field. The settings may
be edited using the „“-“/“+“
keys.

Acoustic signal upon start of the press procedure
In order to inform the user about the actual start of the press
procedure (press plunger moves downwards), an additional acoustic
signal can be played. For that purpose, the global melody (Example
3) is used.

5.5.1.1 Setting the temperature mode

The temperature mode (°C/°F)
and the vacuum mode (mbar/
hPa) can be changed via Selec-
tion – Settings – Mode
.

5.5.1.2 Protocol

Mark the touch button
„Protocol“ by pressing it. It can
now be edited using the +/-
keys. With „Active (table)“, the
program parameters used are
entered into the protocol at the
end of a firing program. With
„Active (table and printer)“, the
protocol is also printed with the
printer connected to the furnace.
By pressing the touch button
„Laboratory name“, the keypad
is displayed and the name of the
laboratory can be entered.
With “Active (table and PC)”,
the protocol can be sent to the
connected PC software instead
of being printed after each firing
program.

Pressing the touch button „Protocol table“ results in the
corresponding screen being displayed. The desired protocol can now
be selected using the +/- keys. The selected protocol may either be
printed or deleted.

5.5.1.3 Configuration of the displays

Scroll to page 2/2 in the
„Settings“ display by means of
the „+“ key and select
„Screen Configuration“.
After pressing the upper touch
button, the „-“/“+“ keys can be
used to determine which screen
should be displayed after a firing
program. The user may select
either the parameter display of
the current program or the
program selection display of the
corresponding group.
By using the lower touch button,
a preferred group number can
be entered. In this way, the „0“
can be used in the program
selection display to toggle

between the current group and

this preferred group.
Use the touch button “preferred operating status” to set whether
the firing curve or the remaining time should be indicated after a
program has started (see chapters 6.2.2 and 6.3.3).

5.5.1.4 Extended settings
Change to page 2/2 in the „Settings“ screen using the „plus“ key
and select „Extended settings“.

Important information

For most of the „extended settings“, the user code (6725)
is required.

The most important settings which can be changed under Extended
settings are described below:

Advertising
This manual is related to the following products: