Ivoclar Vivadent EP5000-G2 User Manual

Page 22

Advertising
background image

22

Group write-protection

Enables the user to lock an entire
group (10 programs and group
name). The respective group
write-protection is activated and
deactivated using an individually
selected code (1-4 digits). If a
group write-protection is active,
the write-protection symbol
shows the corresponding group.

By deactivating the general write-protection (see specify which
subchapter), the write-protection of all groups is deactivated. This
function can also be used if the user has forgotten an individual
group write-protection.

General write-protection

Enables to release or lock the change of the individual firing
programs (name and parameters).

Vacuum quality (absolute)
Defines the vacuum quality (mbar/hPa), which has to be reached by
the vacuum pump when the vacuum is built up during the firing
program. This value is the basis for calculating the vacuum quality
specific to the firing program (see Chapter 5.4 “Parameter vacuum
quality”).

Set the firing hours of the muffle to „0“
If the (heating) muffle is replaced, the firing hours counter can be
reset.

Set the vacuum pump hours to „0“
If the vacuum pump is replaced, the operating hours counter of the
vacuum pump can also be reset.

Standard mode
Temperature control according to standard: DIN 13905-1 “Dentistry
– Dental furnaces – Part 1: Dynamic test method for temperature
measurement with separate thermocouple”.

Load factory settings
Resets all settings (see Chapter 8.4).

Reminder intervals
Interval settings to remind you when the next calibration, service or
dehumidification has to be conducted.

Power-saving key (89)
Power-saving function activated (only possible with the furnace head
closed and the furnace on idle). The display shows the power-saving
icon. Pressing any key ends the power-saving
function.

The energy saving mode (Power Saving Technology) is

available in the EP 5000/G2 only in the firing mode.
In the press mode, the energy saving function is disabled,
as the furnace must fulfil additional requirements.

Ivoclar Vivadent
Only used by the Service Center.

5.5.2 Program Manager

This screen is displayed by
pressing the „Program Manager“
touch button.

5.5.2.1 Renaming the current program or program group

This screen is displayed by
pressing the „Rename“ touch
button. Now, the current
program or the current program
group can be renamed.
If required, the write-protection
has to be unlocked under
Settings – Settings – Extended
settings.

The keyboard is displayed by
tapping the corresponding touch
button. The name of the current
program or program group can
now be edited using the
available touch buttons or
numeric keypad.
If the process is aborted by
pressing the Esc key, the old
name is retained.
The blinking cursor can be

moved by means of the „arrow“ touch buttons. The „Delete“ touch
button can be used to delete an individual character to the left of
the cursor. The entire description can be deleted by pressing the
„Delete all“ touch button.

5.5.2.2. Copying programs

By pressing the „Copy
programs“ touch button, this
screen is displayed.
Here you can set the source and
the target of the copy proce-
dure. The desired touch button
can be selected (black frame) by
slightly tapping on it.
Subsequently, the button can be
edited using the +/- keys or the

numeric keypad. If a memory stick is used, an additional touch
button is displayed.

This screen is displayed by
pressing the touch button
„Copy“. The copy procedure is
executed by pressing the touch
button „Yes, copy“.

Advertising