1 pps, Can bus/event – NavCom RT-3020 Rev.D User Manual

Page 22

Advertising
background image

RT-3020 User Guide - Rev. E

‡

The

GPS

LED

s will blink at the positioning rate

selected.

1 PPS

The RT-3020M has the ability to output a precise pulse
every second that can be used for a variety of Time/
Mark applications where precise timing is critical.

Specifications:

- 12.5ns relative accuracy.

- Better than 100ns absolute accuracy.

- 50 Ohm, TTL level.

- Pulse width, default 100mS, range 10 – 999mS

- Pulse delay, default 0mS, range 0 – 999mS.

- Rising or Falling Edge Synchronization.

Connecting the 1

PPS

output requires a cable with a

BNC male connector, NavCom

P/N

94-310050-3003

0.9m (3ft) long, BNC male to BNC male cable

CAN Bus/Event

The RT-3020M also employs a balanced (differential) 2-
wire

CAN Bus

technology interface, ISO11898 -24V

compliant. The

CAN

interface uses an asynchronous

transmission scheme employing serial binary
interchange and is widely used in the automotive
industry. The data rate is defined as 250K

bps

maximum with Termination resistors used at each end
of the cable. This port/connector is shared with the

Even

t Input.