Connecting and setting the devices, 7 – recording/playback with cascade connections – Teac DA-3000 User Manual

Page 43

Advertising
background image

TASCAM DA-3000

43

7 – Recording/playback with cascade connections

Connecting and setting the devices

Connect the master and slave devices.
Connect the devices in the following manner according to the

synchronization method.

CAUTION

When installing units on top of each other, leave space

between units to allow good heat dispersal.

When mounting them in a rack, leave at least 1U open

above each unit.

8 Synchronizing using S/PDIF with the master unit as

the clock master

Connections

Use a coaxial digital cable to connect the master unit

DIGITAL OUT to the slave unit DIGITAL IN (S/PDIF /

CASCADE).
When connecting a second slave unit, use a coaxial digital

cable to connect the first slave unit DIGITAL OUT to the

second slave unit DIGITAL IN (S/PDIF / CASCADE).

Master unit

Slave unit 1

Slave unit 2

Settings

Press the MENU button to open the

GENERAL

page of the

menu screen. Set the

CLOCK MSTR

and

CASCADE

items as

follows. (See “Setting the master clock” on page 25.) (See

“Setting master and slave units” on page 44.)

GENERAL Page
CLOCK MSTR setting CASCADE setting

Master unit Internal

MASTER

Slave unit

DIN

SLAVE

8 Using the master unit as the clock master for word

clock synchronization

Connections

Use a coaxial digital cable to connect the master unit

DIGITAL OUT to the slave unit DIGITAL IN (S/PDIF /

CASCADE) and a BNC cable to connect the WORD SYNC

THRU/OUT to the slave unit WORD SYNC IN.
When connecting a second slave unit, use a coaxial digital

cable to connect the first slave unit DIGITAL OUT to the

second slave unit DIGITAL IN (S/PDIF / CASCADE) and a

BNC cable to connect the first slave unit WORD SYNC THRU/

OUT to the second slave unit WORD SYNC IN.

Master unit

Slave unit 1

Slave unit 2

ON 75Ω/OFF switch

(WORD OUT)

ON 75Ω/OFF switch

(THRU)

In addition, set the 75Ω ON/OFF [THRU/WORD OUT]

switches on the master and slave units as follows.

ON 75Ω/OFF [THRU/WORD OUT] switch
ON 75Ω/OFF

THRU/WORD OUT

Master unit ON

WORD OUT

Slave unit

OFF

THRU

Slave unit
(last)

ON

WORD OUT

Settings

Press the MENU button to open the

GENERAL

page of the

menu screen. Set the

CLOCK MSTR

and

CASCADE

items as

follows. (See “Setting the master clock” on page 25.) (See

“Setting master and slave units” on page 44.)

GENERAL page
CLOCK MSTR setting CASCADE setting

Master

unit

Internal

MASTER

Slave unit WORD

SLAVE

Advertising