Stapling bed assembly – EXP Computer C4077-90960 User Manual

Page 235

Advertising
background image

Stapling Bed Assembly

1

Remove the Stapling Unit Assembly (see Figure 6-91).

2

Remove the Back Plate (see Figure 6-92).

3

Remove the Stapler Unit Controller PCA (see Figure 6-94).

4

Remove the Top Cover Assembly (see Figure 6-97).

5

Remove the wire frame by pushing both arms of the wire frame toward the
center to clear the retaining notches and lift.

6

Release the brushes bar from the retaining notches and lift upwards.

7

Insert a flat-blade screwdriver into top of the Stapling Bed Assembly and
push gently to release the latches in the front of the stapling bed (see Figure
6-98. callout 2).

8

Remove (3) torx screws that join the stapling bed with the rest of the unit
(see Figure 6-98, callout 3).

9

To remove the Stapling Bed Assembly, lift the edge of the assembly where
the stapler unit resides, then gently lift the entire Stapling Unit Assembly.

To Reinstall:

Replace the Stapling Bed. Replace the Stapling Unit Controller. Replace
the actuator for the paper bin empty sensor.

C a u t i o n

Make sure that the actuator is in its proper place before replacing the
Stapling Bed Assembly (see Figure 6-99, callout 3).