SEQUENCE LINE

There are eight sets of sequence lines built in the speed dome camera. Using LEFT/RIGHT

direction keys to select a line first and then set its sequence points.

SEQUENCE POINT

Up to 32 points can be specified for each sequence line. The sequence points represent the

orders of the preset points that the dome will automatically run, and the bellowing setup items,

PRESET POSITION, SPEED, and DWELL TIME, are related to this item.

PRESET POSITION

Users can assign a specific preset position to the selected sequence point with this item.

SPEED

Users can set the Speed that the dome goes to the next sequence point, and setup speed

range is from 1 ~ 15. Refer to below table for more information.

PAN (degree/sec.)

TILT (degree/sec.)

Speed 1

10

8

Speed 2

23

12

Speed 3

35

22

Speed 4

45

30

Speed 5

55

40

Speed 6

65

50

Speed 7

75

58

Speed 8

185

185

Speed 9

205

210

Speed 10

225

240

Speed 11

250

275

Speed 12

280

305

Speed 13

320

335

Speed 14

365

365

Speed 15

400

400

DWELL TIME

The DWELL TIME is the duration time that the speed dome will stay at the sequence point,

and the range is from <0> to <127> seconds. The speed dome will go to the next sequence

point when the DWELL TIME is up. If the setting is <0>, the speed dome will stay at this

sequence point until users manually move the speed dome.