9 advance menu ___display – ARM Electronics RDVR16A User Manual

Page 25

Advertising
background image

21

5.9 ADVANCE MENU ___DISPLAY

5.9 ADVANCE MENU ___DISPLAY

Move the cursor to the “DISPLAY”, and press ”ENTER”, then the screen will show the
following options.

DISPLAY

DISPLAY

TITLE DISPLAY

ON

DATE DISPLAY

ON

HDD INFO

ON

LOSS SCREEN

BLUE

PLAYBACK INFO

NORMAL

DWELL DURATION (SEC)

2

DE-INTERLACE

ON

1)

TITLE DISPLAY:
Turn the camera title display on / off.

2)

DATE DISPLAY:
Turn the date display on / off.

3)

HDD INFO”
Turn the information of internal HDD and DISK ARRAY display on / off.

4)

LOSS SCREEN”
Set the color of video loss screen (Blue or Black)

5)

PLAYBACK INFO:
Set the position where PLAYBACK INFO will be indicated (center or normal (on the
button of left-hand side of the screen)).

6)

TS :
The sensitivity towards how long the object gets triggered. The smaller the
value is, the higher sensitivity for motion detection.
The highest sensitivity setting is 00, and the lowest sensitivity setting is 15.
The default setting is 02.

7)

RE :
The value of RE is a reference for detection. The default value is 10, which
means DVR will compare 10 continuous images at one time according to the
sensitivity of LS, SS, TS simultaneously. Therefore the bigger the value is, the
higher sensitivity for motion detection.

8)

ALARM:
Select LOW / HIGH for the alarm polarity. The default alarm value is OFF.

9)

UP / DOWN:
Select “UP” to go to the previous page; Select “DOWN” to go the next page.
Targets set in the AREA.