170

If the BFD detects that the link fails, it informs the track entry of the link failure. The track module then

sets the track entry to the Negative state.

If the BFD detects that the link is normal, the track module sets the track entry to the Positive state.

For more information about BFD, see the chapter “BFD configuration.”

Configuration prerequisites

Before you associate track with BFD, configure the source address of the BFD echo packets.

Configuration procedure

Follow these steps to associate track with BFD:

To do…

Use the command…

Remarks

Enter system view

system-view

Create a track entry, associate it
with the BFD session, and specify
the delay time for the track module

to notify the associated application

module when the track entry status

changes

track track-entry-number bfd echo interface
interface-type interface-number remote ip
remote-ip local ip local-ip [ delay { negative

negative-time | positive positive-time } * ]

Required
No track entry is created

by default.

NOTE:

When associating track with BFD, do not configure the virtual IP address of a VRRP group as the local or
remote address of a BFD session.

Associating track with interface management

The interface management module monitors the physical status or network-layer protocol status of the

interface. The interface management module functions as follows when it is associated with a track entry:

When the physical or network-layer protocol status of the interface changes to up, the interface

management module informs the track module of the change and the track module sets the track
entry to Positive.

When the physical or network-layer protocol status of the interface changes to down, the interface
management module informs the track module of the change and the track module sets the track

entry to Negative.

Follow these steps to associate track with interface management:

To do…

Use the command…

Remarks

Enter system view

system-view

Create a track entry, associate it

with the interface management
module to monitor the physical

status of an interface, and specify

the delay time for the track module

to notify the associated application
module when the track entry status

changes

track track-entry-number interface

interface-type interface-number [ delay
{ negative negative-time | positive

positive-time } * ]

Required
Use either approach
No track entry is created by

default.