Verify the configurations – H3C Technologies H3C S10500 Series Switches User Manual

Page 38

Advertising
background image

29

[DeviceE] cfd meplist 1001 4002 5001 service-instance 1

[DeviceE] interface gigabitethernet 1/0/4

[DeviceE-GigabitEthernet1/0/4] cfd mep 5001 service-instance 1 inbound

[DeviceE-GigabitEthernet1/0/4] cfd mep service-instance 1 mep 5001 enable

[DeviceE-GigabitEthernet1/0/4] quit

5.

Configure MIPs.

# Configure the MIP generation rule in service instance 1 on Device B as explicit.

[DeviceB] cfd mip-rule explicit service-instance 1

# Configure the MIP generation rule in service instance 2 on Device C as default.

[DeviceC] cfd mip-rule default service-instance 2

6.

Configure CC.

# On Device A, enable the sending of CCM frames for MEP 1001 in service instance 1 on

GigabitEthernet 1/0/1.

[DeviceA] interface gigabitethernet 1/0/1

[DeviceA-GigabitEthernet1/0/1] cfd cc service-instance 1 mep 1001 enable

[DeviceA-GigabitEthernet1/0/1] quit

# On Device B, enable the sending of CCM frames for MEP 2001 in service instance 2 on
GigabitEthernet 1/0/3.

[DeviceB] interface gigabitethernet 1/0/3

[DeviceB-GigabitEthernet1/0/3] cfd cc service-instance 2 mep 2001 enable

[DeviceB-GigabitEthernet1/0/3] quit

# On Device D, enable the sending of CCM frames for MEP 4001 in service instance 2 on
GigabitEthernet 1/0/1, and enable the sending of CCM frames for MEP 4002 in service instance 1 on

GigabitEthernet 1/0/3.

[DeviceD] interface gigabitethernet 1/0/1

[DeviceD-GigabitEthernet1/0/1] cfd cc service-instance 2 mep 4001 enable

[DeviceD-GigabitEthernet1/0/1] quit

[DeviceD] interface gigabitethernet 1/0/3

[DeviceD-GigabitEthernet1/0/3] cfd cc service-instance 1 mep 4002 enable

[DeviceD-GigabitEthernet1/0/3] quit

# On Device E, enable the sending of CCM frames for MEP 5001 in service instance 1 on

GigabitEthernet 1/0/4.

[DeviceE] interface gigabitethernet 1/0/4

[DeviceE-GigabitEthernet1/0/4] cfd cc service-instance 1 mep 5001 enable

[DeviceE-GigabitEthernet1/0/4] quit

Verify the configurations

1.

Verify the LB function.

When the CC function detects a link fault, use the LB function to locate the fault.
# Enable LB on Device A to check the status of the link between MEP 1001 and MEP 5001 in service

instance 1.

[DeviceA] cfd loopback service-instance 1 mep 1001 target-mep 5001

Loopback to 0010-FC00-6515 with the sequence number start from 1001-43404:

Reply from 0010-FC00-6515: sequence number=1001-43404 time=5ms

Reply from 0010-FC00-6515: sequence number=1001-43405 time=5ms

Reply from 0010-FC00-6515: sequence number=1001-43406 time=5ms