Displaying and maintaining cfd, Cfd configuration example, Network requirements – H3C Technologies H3C S10500 Series Switches User Manual

Page 35

Advertising
background image

26

Displaying and maintaining CFD

To do...

Use the command...

Remarks

Display CFD status

display cfd status [ | { begin | exclude |
include } regular-expression ]

Available in any view

Display the CFD protocol version

display cfd version [ | { begin | exclude |
include } regular-expression ]

Available in any view

Display MD configuration
information

display cfd md [ | { begin | exclude |
include } regular-expression ]

Available in any view

Display MA configuration
information

display cfd ma [ [ ma-name ] md { md-name
| level level-value } ] [ | { begin | exclude |

include } regular-expression ]

Available in any view

Display service instance
configuration information

display cfd service-instance [ instance-id ]
[ | { begin | exclude | include }

regular-expression ]

Available in any view

Display MEP list in a service
instance

display cfd meplist [ service-instance
instance-id ] [ | { begin | exclude | include }

regular-expression ]

Available in any view

Display MP information

display cfd mp [ interface interface-type
interface-number
] [ | { begin | exclude |

include } regular-expression ]

Available in any view

Display the attribute and running
information of the MEPs

display cfd mep mep-id service-instance
instance-id [ | { begin | exclude | include }
regular-expression ]

Available in any view

Display LTR information received
by a MEP

display cfd linktrace-reply [ service-instance
instance-id [ mep mep-id ] ] [ | { begin |
exclude | include } regular-expression ]

Available in any view

Display the information of a remote
MEP

display cfd remote-mep service-instance
instance-id mep mep-id [ | { begin | exclude

| include } regular-expression ]

Available in any view

Display the content of the LTR
messages received as responses to

the automatically sent LTMs

display cfd linktrace-reply auto-detection
[ size size-value ] [ | { begin | exclude |

include } regular-expression ]

Available in any view

CFD configuration example

Network requirements

As shown in

Figure

8

:

The network comprises five devices and is divided into two MDs: MD_A (level 5) and MD_B (level
3). All ports belong to VLAN 100, and the MAs in the two MDs all serve VLAN 100.

MD_A has three edge ports: GigabitEthernet 1/0/1 on Device A, GigabitEthernet 1/0/3 on
Device D, and GigabitEthernet 1/0/4 on Device E, and they are all inward-facing MEPs. MD_B

has two edge ports: GigabitEthernet 1/0/3 on Device B and GigabitEthernet 1/0/1 on Device D,

and they are both outward-facing MEPs.

Advertising