Configuring link monitoring, Configuring errored symbol event detection, Configuring errored frame event detection – H3C Technologies H3C S10500 Series Switches User Manual

Page 22

Advertising
background image

13

To do…

Use the command…

Remarks

Enter system view

system-view

Configure the Ethernet OAM
handshake packet transmission

interval

oam timer hello interval

Optional
1000 millisecond by default.

Configure the Ethernet OAM
connection timeout timer

oam timer keepalive interval

Optional
5000 milliseconds by default.

CAUTION:

After the timeout timer of an Ethernet OAM connection expires, the local OAM entity ages out its
connection with the peer OAM entity, causing the OAM connection to be disconnected. H3C recommends

that you set the connection timeout timer to at least five times the handshake packet transmission interval,

ensuring the stability of Ethernet OAM connections.

Configuring link monitoring

NOTE:

After Ethernet OAM connections are established, the link monitoring periods and thresholds configured in
this section take effect on all Ethernet ports automatically.

Configuring errored symbol event detection

Follow these steps to configure errored symbol event detection:

To do…

Use the command…

Remarks

Enter system view

system-view

Configure the errored
symbol event detection

interval

oam errored-symbol period period-value

Optional
1 second by default.

Configure the errored
symbol event triggering

threshold

oam errored-symbol threshold
threshold-value

Optional
1 by default.

Configuring errored frame event detection

Follow these steps to configure errored frame event detection:

To do…

Use the command…

Remarks

Enter system view

system-view

Configure the errored frame
event detection interval

oam errored-frame period period-value

Optional
1 second by default.

Configure the errored frame
event triggering threshold

oam errored-frame threshold
threshold-value

Optional
1 by default.