Connecting the irf member switches in one rack – H3C Technologies H3C S5800 Series Switches User Manual

Page 92

Advertising
background image

82

optical fibers. If the IRF member switches are all in one equipment room, choose SFP+ cables or twisted

pair cables.

Table 35

lists the SFP+ transceivers and SFP+ cables available for IRF connections.

Table 35 SFP+ transceiver modules and SFP+ cables available for IRF connections

Transceiver/cable

Central

wavelength Connector Fiber

Max transmission

distance

10 GE SFP+ transceiver

SFP-XG-SX-MM850-A 850

nm LC

50/125 μm multimode
optical fiber

300 m (984.3 ft.)

SFP-XG-LX220-MM1310

1310 nm

LC

62.5/125 μm multimode

optical fiber

220 m (721.8 ft.)

SFP-XG-LX-SM1310 1310

nm

LC

9/125 μm single mode
optical fiber

10 km (about 6.21
mi)

10 GE SFP+ cable

LSWM1STK

N/A

N/A

SFP+ cable

0.65 m (2.1 ft)

LSWM2STK

N/A

N/A

SFP+ cable

1.2 m (3.9 ft)

LSWM3STK

N/A

N/A

SFP+ cable

3 m (9.8 ft)

LSTM1STK

N/A

N/A

SFP+ cable

5 m (16.4 ft)

LSTM2STK

N/A

N/A

SFP+ cable

7 m (22.97 ft)

The following subsections describe several H3C recommended IRF connection schemes. All these
schemes use a ring topology.

IMPORTANT:

In these schemes, all physical IRF ports are located on the same side. If physical IRF ports are on different
sides, you must measure the distance between them to select an appropriate cable.

Connecting the IRF member switches in one rack

Use short-haul and long-haul SFP+ cables to connect the IRF member switches (10 switches in this

example) in a rack as shown in

Figure 93

. The switches in the ring topology (see

Figure 94

) are in the

same order as connected in the rack.

Advertising