11 bpdu tunnel configuration example, I. network requirements, Ii. network diagram – H3C Technologies H3C S3100 Series Switches User Manual

Page 223: Iii. configuration procedure, 11 bpdu tunnel configuration example -48

Advertising
background image

Operation Manual – MSTP
H3C S3100-52P Ethernet Switch

Chapter 1 MSTP Configuration

1-48

1.11 BPDU Tunnel Configuration Example

I. Network requirements

z

S3100-52P Ethernet switches operate as the access devices of the operator’s
network, that is, Switch C and Switch D in the network diagram.

z

S2000 series switches operate as the access devices of the user’s network, that is,
Switch A and Switch B in the network diagram.

z

Switch C and Switch D are connected to each other through the configured trunk
ports of the switches. The BPDU Tunnel function is enabled in system view, thus
implementing transparent transmission between the user’s network and the
operator’s network.

II. Network diagram

Switch C

Switch A

E 0/1

Switch D

Switch B

E 1/0/2

E 0/1

E 1/0/1

Switch C

Switch A

E 1/0/1

E 0/1

Switch D

Switch B

E 0/1

E 1/0/2

Switch C

Switch A

E 0/1

Switch D

Switch B

E 1/0/2

E 0/1

E 1/0/1

Switch C

Switch A

E 1/0/1

E 0/1

Switch D

Switch B

E 0/1

E 1/0/2

Figure 1-8

Network diagram for BPDU Tunnel configuration

III. Configuration procedure

1) Configure Switch A

# Enable RSTP.

<H3C> system-view

[H3C] stp enable

# Add Ethernet 0/1 to VLAN 10.

[H3C] vlan 10

[H3C-Vlan10] port Ethernet 0/1

2) Configure Switch B

# Enable RSTP.

<H3C> system-view

[H3C] stp enable

# Add Ethernet 0/1 to VLAN 10.

Advertising