Operation Manual – NTP

H3C S3100-52P Ethernet Switch

Chapter 1 NTP Configuration

1-19

Clock stratum: 3

Reference clock ID: 3.0.1.31

Nominal frequency: 250.0000 Hz

Actual frequency: 249.9992 Hz

Clock precision: 2^19

Clock offset: 198.7425 ms

Root delay: 27.47 ms

Root dispersion: 208.39 ms

Peer dispersion: 9.63 ms

Reference time: 17:03:32.022 UTC Thu Sep 6 2001 (BF422AE4.05AEA86C)

The output information indicates that S3100-52P-1 is synchronized to H3C3, with the
clock stratum level of 3, one level lower than that of H3C3.
# View the information about the NTP sessions of S3100-52P-1 and you can see that a
connection is established between S3100-52P-1 and H3C3.

[S3100-52P-1] display ntp-service sessions

source reference stra reach poll now offset delay disper

**************************************************************************

[1]3.0.1.31 127.127.1.0 2 1 64 377 26.1 199.53 9.7

note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured

1.7.4 Configuring NTP Multicast Mode

I. Network requirements

The local clock of H3C3 is set to the NTP master clock, with a clock stratum level of 2.
H3C3 advertises multicast packets through Vlan-interface2.
S3100-52P-1 and S3100-52P-2 respectively listen to multicast packets through their
own Vlan-interface2.

Note:

This example assumes that H3C3 is a switch that supports the local clock being the
master clock.