1 configuration prerequisites, 2 configuring bpdu tunnel, 3 bpdu tunnel configuration example – H3C Technologies H3C S3100 Series Switches User Manual

Page 614: I. network requirements, 3 bpdu tunnel configuration example -3

Advertising
background image

Operation Manual – VLAN VPN

H3C S3100-52P Ethernet Switch

Chapter 1 VLAN-VPN Configuration

2-3

2.2.1 Configuration Prerequisites

One or more protocols among LACP, NDP, CDP, and VTP operate properly on the
devices.

2.2.2 Configuring BPDU Tunnel

Table 2-1

Configure BPDU Tunnel

Operation

Command

Description

Enter system view

system-view

Enable the function in system

view

bpdu-tunnel uplink
interface-list

Enter Ethernet

port view

interface
interface-type
interface-number

Enable the BPDU

Tunnel function

bpdu-tunnel uplink

Set the

port to

be a

BPDU

Tunnel

uplink

port

Enable

the

function

in

Ethernet

port view Return to system

view

quit

You can enable

the BPDU

Tunnel in

system view or

in Ethernet

view.
By default, NDP

is enabled

globally.

Enter Ethernet port view

interface
interface-type
interface-number

-

Enable the BPDU Tunnel function for

the packets of a specific protocol

bpdu-tunnel

{ lacp |

ndp

| cdp | vtp }

Required
By default, the

BPDU Tunnel

function is

disabled on a

port.

2.3 BPDU Tunnel Configuration Example

I. Network requirements

z

Custimer1 and Customer2 are access devices operating in a user network.

z

Provider1 and Provider2 are access devices operating in the operator’s network.
They are interconnected through their trunk ports, as shown in Figure 2-4.

z

Enable the BPDU Tunnel function for NDP packets on the Ethernet1/0/1 and
Ethernet1/0/4 port shown in the Figure 2-4.Set the port Ethernet1/0/2 and
Ethernet1/0/3 to be BPDU Tunnel uplink ports.

Advertising