101

MPU LEDs

An SR8800 MPU has the following LEDs (from left to right):

CF card status LED

Network management port LEDs

LPU status LEDs

MPU status LEDs

Figure 69 MPU LEDs

(1) CF card status LED (CFS)

(2) Network management port LED
(ACT)

(3) Network management port LED
(LINK)

(4) MPU status LED (SFS)

(5) MPU status LED (ACT)

(6) MPU status LED (RUN)

(7) MPU status LED (ALM)

(8) LPU status LED (RUN)

(9) LPU status LED (ALM)

The appearance of SR8800 MPUs varies by MPU model.

Figure 69

takes SR02SRP1F3 for illustration.

CF card status LED

Table 43 CF card status LED description

LED Status

Description

CFS (green)

Steady on

The CF card is in position and idle.

Flashing

The CF card is in position and performing read/write
operations. Do not unplug it.

Off

The CF card is out of position or offline. You can plug in or
unplug it.

NOTE:

When the CF card LED is on, do not unplug the CF card. To unplug it, execute the umount command in
user view to uninstall the CF card, and then unplug the CF card when the CF card LED is off.