Replacing a transceiver module – H3C Technologies H3C SR8800 User Manual

Page 91

Advertising
background image

81

Figure 66 Replacing a CF card

Replacing a transceiver module

The replacement procedures of XFP and SFP transceiver modules are similar. This section takes an SFP

transceiver module as an example.

CAUTION:

When installing or removing an SFP transceiver module, do not touch the golden finger of the SFP
transceiver module.

To replace a transceiver module:

1.

Put on an ESD wrist strap, and make sure the wrist strap makes good skin contact and is well
grounded.

2.

Remove the optical fibers from the SFP transceiver module, pivot the clasp down to the horizontal
position, and then pull SFP the transceiver module out of the socket, as shown in

Figure 67

.

3.

Put the removed SFP transceiver module in an antistatic bag or its original shipping materials.

4.

Unpack a new SFP transceiver module, pivot the clasp of the SFP transceiver module upward to the

vertical position so that it catches a knob on the top of the SFP transceiver module, and then,
holding both sides of the SFP transceiver module, gently push the SFP transceiver module into the

socket until it has close contact with the socket (you can feel that the top and bottom spring tabs

catch in the socket), as shown in

Figure 68

.

5.

Connect the optical fibers to the new SFP transceiver module.

Advertising