Level 2r system power-on procedure – Grass Valley K2 Storage System Instruction Manual v.3.2 Aug.01 2007 User Manual

Page 119

Advertising
background image

July 3, 2007

K2 Storage System Instruction Manual

119

Level 2R system power-on procedure

Level 2R power-on procedure page 2

Power on the primary
media file system/
database K2 Media
Server. This is the
server that was
primary when you last
powered down the K2
Storage System.

From the control
point PC, in the K2
System
Configuration
application, open

Server Control
Panel

.

Begin record/play

operations.

Level 2R K2 Storage

System power-on complete

Put the K2 Media Server into service:
In Server Control Panel, click

Start

to

start Failover Monitor.

No

In Server Control Panel,
check the Failover Monitor
indicator.

Yes

No

Yes

Green

indicator?

Elapsed time:

3 minutes

Power on K2
Media Clients.

Power on backup media file
system/database K2 Media Server

In Server Control Panel, check
the media file system indicator.

Check all

Server

Control

Panel

indicators

No

Yes

In Server
Control Panel,
check the
media file
system
indicator.

Yes

No

Green

indicator?

Elapsed time:

30 seconds

Green

indicator?

Elapsed time:

3 minutes

Green

indicators?

Elapsed time:

3 minutes

From the control point PC, at the command
prompt, ping the K2 Media Server.

No

Yes

K2

Media Server

responds to ping?

Elapsed time:

3 minutes

Begin record/play

operations.

Power on generic
iSCSI clients.

In Server Control

Panel, click

Start

Advertising