K2 Storage System Instruction Manual

July 3, 2007

Chapter 11 Administering and maintaining the K2 Storage System

enabled to become the “backup” RAID controller.

Configuring Level 2 RAID chassis network and SNMP settings

Through Storage Utility you can configure the following settings on a RAID chassis:

• IP address

• Subnet mask

• Gateway Address

• SNMP trap destinations

For the Level 2 RAID chassis, network and SNMP settings are set and stored on the
LAN card. Therefore, if the RAID chassis has two RAID controllers, they are
configured as a single device, as in the following procedure.

1. In the Storage Utility, right-click the icon for a RAID controller and select

Configuration | Network Properties

. The Network Settings dialog box opens.

2. Enter network settings.

3. For each SNMP manager to which you want to send SNMP trap messages, enter

the IP address of the PC hosting the manager. For monitoring with NetCentral,
enter the IP address of the NetCentral server PC.

4. Click

OK

to save settings and close.

5. Restart the RAID chassis to put SNMP configuration changes into effect.