Removing the Library From the Rack
PLS200 Library Installation and Operation
73
Removing the Library From the Rack
WARNING: The library weighs 137 – 167 pounds (62 – 76 kg). To avoid
possible injury, you need at least 4 people, or 2 people and a small fork lift, to
lift the library.
Preparation
• Obtain a fork lift or enlist the help of at least three additional people.
• Obtain the following tools:
- T-15 TORX driver
- T-25 TORX driver
Removing the library
To remove the library from the rack:
1. Extend the extension support legs on the rack.
2. Remove the air filter grilles from the front of the library by lifting on the
outside edges and pulling the grilles away from the library.
3. Use a T-25 TORX driver to remove the two pan head screws that secure the
library to the rack, as shown in Figure 6-3. A clip nut may have been
installed over the screw hole on the rack.
!