Data...
The Data... function selects the data table view of stored records.
DMS/DD
Toggles between the current presentation of degrees/minutes/
seconds and decimal degrees for angular measurements.
Dout
Defines the logic state of one of the 12 parallel output pins to:
When the Dout function is selected, additional screens are provided
for pin and logic level assignment.
DRO
The DRO function selects the DRO view of current values.
State
Description
Off
Logic 0 (0 volts)
On
Logic 1 (5 volts)
Toggle
Changes from one logic level to the other on a
specified output pin.
Logic ground is wired to pins 18 through 25.
Pin 13
Pin 1
Pin 25
Pin 14
Dout 8 7 6 5 4 3 2 1 9
Ground Reference 12 11 10 Dout