Nominal with -- tolerances, 3 s o ft wa re s e tu p – HEIDENHAIN ND 2100G User Manual
Page 87

ND 2100G GAGE-CHEK
87
2
.3
S
o
ft
wa
re
s
e
tu
p
Nominal with -- tolerances
A nominal value is displayed with tolerances entirely on the minus side
of nominal.
To specify a range of tolerances below the nominal value (- Tolerance):
U
Press the +/- soft key
U
Enter the low end of the negative tolerance range into the - Max, -
Limit and -Warn fields
U
Enter the Nominal value
U
Enter the high end of the negative tolerance range into the + Warn
field
U
Press the ++ /-- soft key to change the field to - Warn
U
Repeat this procedure for the + Limit and + Max fields. This
establishes the upper end of the negative range of acceptable
tolerances.
Nominal and -- tolerances for dimension A.
Bar graph showing -- tolerances.
3 mm nominal
-0.01 Nom + Max
-0.02 Nom + Limit
-0.03 Nom + Warning
-0.05 Nom - Warning
-0.06 Nom - Limit
-0.07 Nom - Min