Delete modal program information: m142, Delete basic rotation: m143 – HEIDENHAIN iTNC 530 (340 422) ISO programming User Manual
Page 209

HEIDENHAIN iTNC 530
209
7.
4 M
isc
ellan
e
ou
s F
u
n
c
tio
n
s
f
o
r Cont
our
ing
Beha
vior
Delete modal program information: M142
Standard behavior
The TNC resets modal program information in the following situations:
n
Select a new program.
n
Execute a miscellaneous function M02, M30, or an N999999 %...
block (depending on Machine Parameter 7300).
n
Defining cycles for basic behavior with a new value
Behavior with M142
All modal program information except for basic rotation, 3-D rotation
and Q parameters are reset.
Effect
M142 is effective only in the block in which it is programmed.
M142 becomes effective at the start of the block.
Delete basic rotation: M143
Standard behavior
The basic rotation remains in effect until it is reset or is overwritten
with a new value.
Behavior with M143
The TNC erases a programmed basic rotation from the NC program.
Effect
M143 is effective only in the block in which it is programmed.
M143 becomes effective at the start of the block.