14.8 D
a
tu
m Set
ting with a 3-D T
o
uc
h Pr
obe
Center line as datum
U
Select the probe function by pressing the PROBING
soft key.
U
Position the touch probe near the first touch point
U
Select the probing direction by soft key.
U
Probing: press the NC Start button
U
Position the touch probe near the second touch point
U
Probing: press the NC Start button
U
Datum:
Enter the coordinate of the datum in the menu
window, confirm with the SET DATUM soft key, or
write the value to a table (see "Writing the measured
values from touch probe cycles in datum tables", page
568, or see "Writing the measured values from touch
probe cycles in the preset table", page 569, or see
"Storing measured values in the pallet preset table",
page 570)
U
To terminate the probe function, press the END key