4 CC-Link Option Components

10

YASKAWA ELECTRIC SIEP C730600 44A YASKAWA AC Drive-Option Card CC-Link Technical Manual

CC-Link Option LED Display

Table 3 CC-Link Operation LED Status

Setting Station Address

Set drive parameter F6-10 to a station address (Range 1 to 64) unique to the network. If set to 0, the L.ERR light will turn on and a Station Address

Error (AEr) will occur.

Name

Indication

Operating Status

Remarks

Color

Status

L.RUN

Green

ON

Normal operation

• Receiving data normally

OFF

Timed out

• Timed out waiting to receive
• Logging onto the network
• During reset

L.ERR

Red

ON

CRC error

• CRC error
• Station address setting error (F6-10 = 0)

OFF

During communications

• Normal communications
• During reset

SD

Red

ON

Sending data

• Sending data

Note: LED may appear to flash with slower baud rates.

OFF

No data transfer

• No data being sent
• During reset

RD

Red

ON

Detecting data received

• Detecting data that was received

Note: LED may appear to flash with slower baud rates.

OFF

Waiting for data

• Data not yet received
• During reset