10 cc-link code numbers – Yaskawa 1000 Series Drive Option - CC-Link Technical Manual User Manual

Page 31

Advertising
background image

10 CC-Link Code Numbers

YASKAWA ELECTRIC

SIEP C730600 44A YASKAWA AC Drive-Option Card CC-Link Technical Manual

31

124H

(1017H)

Fault contents 5

0

Excessive PID feedback (FbH)

0041H

1

External fault (input terminal S1) (EF1)

0042H

2

External fault (input terminal S2) (EF2)

0043H

3

Mechanical weakening detection 1 (oL5)

0044H

4

Mechanical weakening detection 2 (UL5)

0045H

5

Current offset fault (CoF)

0046H

6

Reserved

7

Reserved

8

DriveWorksEZ fault (dWFL)

0049H

9

Reserved

A

Reserved

B

Reserved

C

Reserved

D

Reserved

E

Reserved

F

Reserved

130H

(101CH)

CPF contents 1

0

Reserved

1

Reserved

2

A/D conversion error (CPF02)

0083H

3

PWM data error (CPF03)

0084H

4

Reserved

5

Reserved

6

EEPROM data error (CPF06)

0087H

7

Terminal board communication error (CPF07)

0088H

8

EEPROM serial communication fault (CPF08)

0089H

9

Reserved

A

Reserved

B

RAM fault (CPF11)

008CH

C

Flash memory fault (CPF12)

008DH

D

Watchdog circuit exception (CPF13)

008EH

E

Control circuit fault (CPF14)

008FH

F

Reserved

131H

(101DH)

CPF contents 2

0

Clock fault (CPF16)

0091H

1

Timing fault (CPF17)

0092H

2

Control circuit fault (CPF18)

0093H

3

Control circuit fault (CPF19)

0094H

4

Hardware fault at power up (CPF20)

0095H

5

Hardware fault at communication start up (CPF21)

0096H

6

A/D conversion fault (CPF22)

0097H

7

PWM feedback fault (CPF23)

0098H

8

Drive capacity signal fault (CPF24)

0099H

9

Reserved

A

CPF26 Control Circuit Fault

009BH

B

CPF27 Control Circuit Fault

009CH

C

CPF28 Control Circuit Fault

009DH

D

CPF29 Control Circuit Fault

009EH

E

CPF30 Control Circuit Fault

009FH

F

CPF31 Control Circuit Fault

00A0H

Extended Command Code

(Monitor Code)

Fault Name

Fault Code (U2, U3)

BIT

Advertising