1. Notes on Application

Notes

Check Item

Usage condition in ∑-II

Usage of ∑-V

Using S-phase output of absolute

encoder

S-phase output is not available in

SGDV. There are no alternatives.

Please use the multi-turn data and

initial incremental pulse. Or, please

read data through PC communication

(RS-422).

Using reference input magnification

function

The reference input magnification

function is not available in SGDV. There

are no alternatives. Switch by a host

controller

or

MECHATROLINK

communication.

Using auto tuning function

The same auto-tuning function as Σ-II is

not provided in SGDV. The tuneless

function is the alternative function.

Please use the advanced auto-tuning

function

or

moment

of

inertia

identification function of SigmaWin +

when you need to know the moment of

inertia ratio.

Using speed bias function

The speed bias function is not provided

in SGDV. The positioning time can be

shortened by using "Positioning setting

(model following control)" of the

advanced auto-tuning function.

Using auto gain switch function

The auto-gain function is not provided

in SGDV. There are no alternatives.

Please switch by using C-SEL signal in

a host controller or MECHATROLINK

communication.

Using SGDM/SGDH Type

Servo Amplifier

Using duct ventilation type

Please inquire to the factory. Although

there is a model that corresponds to the

duct ventilation type but the capacity is

limited and the installation size is

different.

Using Application Module

None

N/A