Yaskawa Sigma-II Large Capacity User Manual

Page 6

Advertising
background image

<Single phase AC200V specification>

・Three-phase circuit AC200V is standard In the ∑-V series servo

amplifier.

Please change the parameter "Function selection switch B" when

using single-phase power supply. (Pn00B.2=1)

(Contents are the same as the motor voltage specifications)

Connect to terminal L1 and L2 when using the single-phase power

supply.

Please note that the torque-speed characteristic is different from

the three-phase circuit power supply specifications.

Also please note that the size of 1.5kW single-phase AC200V servo

amplifier (SGDV-120A

A008000) is the same as the 3kW

three-phase AC200V specification (SGDV-200A

A).

<DC power supply input>

・Please change the parameter "Function selection switch 1" when

using DC power supply input. (Pn001.2=1)

Note) Connect the main circuit DC power supply only after

changing the parameter.

Control

Circuit

<Confirmation of wiring>

・ The control circuit connector, numbers of pins, array order might

be different between the servo amplifier in-use and the

replacement servo amplifier.

Software

<Confirmation of special software version>

・ Confirm whether the software of the servo amplifier in-use is

standard software from the version number. Contact Yaskawa

with the version number if you are not sure the software is

standard or not.

Software version can be confirmed with the handheld digital

operator, or function Fn012 of built-in panel operator, and product

data reading function of the supporting software SigmaWin+.

Servo

Amplifier

Software

Constant

< Confirmation of user constants >

・Confirm the user constants of the servo amplifier in-use.

SigmaWin + has a function to convert from the user constants of

∑-II into the parameter of ∑- V.

・Factory default setting of ∑-V servo adjustment parameter is “enable

tuneless” (Pn170.0=1). Change it to “disable tuneless”

(Pn170.0=0) when you perform the servo adjustment.

Advertising