Yaskawa AC Drive Z1000 HVAC User Manual

Page 26

Advertising
background image

A

B

B

C

A – SW1 (ON)
B – Screw (OFF)

C – SW2 (ON)

Figure i.11 EMC Filter Switch Location (4A0124)

A

B

B

C

A – SW1 (ON)
B – Screw (OFF)

C – SW2 (ON)

Figure i.12 EMC Filter Switch Location (2A0143 to 2A0273 and 4A0156 to 4A0240)

A

B

B

C

A – SW1 (ON)
B – Screw (OFF)

C – SW2 (ON)

Figure i.13 EMC Filter Switch Location (4A0302)

If the SW1/SW2 screws are missing, install proper size screws with the proper tightening torque as shown in

Table i.8

.

NOTICE: Do not use screws of different sizes in SW1 and SW2. Failure to comply may cause overheating.

Table i.8 SW1/SW2 Screw Sizes and Tightening Torques

Drive Model

SW1/SW2 Screw Size

Tightening Torque

2A0011

2A0017

4A0005

4A0008

4A0011

M3 × 16

0.5 to 0.6 N

•m

2A0024

2A0031

4A0014

4A0021

4A0027

M3 × 16

0.5 to 0.6 N

•m

2A0046

2A0059

4A0034

4A0040

M3 × 16

0.5 to 0.6 N

•m

2A0075

2A0088

2A0114

4A0052

4A0065

4A0077

4A0096

M5 × 30

2 to 2.5 N

•m

4A0124

M5 × 25

2 to 2.5 N

•m

i.3 Electrical Installation Safety

26

YASKAWA ELECTRIC TOEP YAIZ1U 01A YASKAWA AC Drive – Z1000 Safety Precautions