7 PROFIBUS-DP Option Data and I/O Maps

YASKAWA ELECTRIC TOBP C730600 23C 1000-Series Option SI-P3/V, SI-P3/T Installation Manual

31

Table 11 Extended Data 2 Register Map

Output (Master Device – Drive)

Input (Drive – Master Device)

Byte

<1> Unit depends on the setting of o1-03 (Digital Operator Display Scaling). When the drive is operating in the V/f

Control mode, the drive's output frequency becomes the input data.

Description

Byte

Description

0

Operation Command (High Byte)

0

Drive Status (High Byte)

1

Operation Command (Low Byte)

1

Drive Status (Low Byte)

2

Frequency Reference (High Byte)

2

Motor Speed (High Byte)

<1>

3

Frequency Reference (Low Byte)

3

Motor Speed (Low Byte)

<1>

4

MEMOBUS/Modbus Function Code

4

MEMOBUS/Modbus Function Code

5

MEMOBUS/Modbus Starting Register Address
(High Byte)

5

MEMOBUS/Modbus Starting Register Address
(High Byte)

6

MEMOBUS/Modbus Starting Register Address
(Low Byte)

6

MEMOBUS/Modbus Starting Register Address
(Low Byte)

7

MEMOBUS/Modbus Data Length

7

MEMOBUS/Modbus Data Length

8

MEMOBUS/Modbus Data 1 (High Byte)

8

MEMOBUS/Modbus Data 1 (High Byte)

9

MEMOBUS/Modbus Data 1 (Low Byte)

9

MEMOBUS/Modbus Data 1 (Low Byte)

10

Reserved

10

Reserved

11

Handshaking Register

11

Handshaking Register