Appendix A - Optional Equipment and Accessories

Bracket to enclosure

Torx screws

Controller Bracket

Mounting Holes

Enclosure

Charge Control Bracket

(left side)

Left Front View

Right Front View

Controller Bracket

Mounting Holes

Enclosure

Bracket to enclosure

Torx screws

Charge Control Bracket

(right side)

G

F

D

C

B

A

E

E

F

D

A

B

C

G

Refer to Figure A1-2 to locate the holes you will use to attach the charge controller to the bracket.
Before mounting the bracket, use the provided T20 Torx drive, thread forming screws to pre-thread
your selected mounting holes. It is easier to thread the holes now rather than doing it after the
bracket and controller have been installed.

After pre-threading your particular bracket hole(s), refer to Figure A1-3 to locate the enclosure
mounting holes you will use to attach the bracket to the enclosure. Before you mount the charge
controller to the attached bracket, remove the appropriate knockout from the side of the controller
and an adjacent knockout on the side of the enclosure. This allows you to use a 1” close nipple
with two locknuts to secure the charge controller to the enclosure (in addition to the bracket),
and provides a path to run the necessary wiring between the two units. Mount the controller to
the attached bracket using the supplied hardware. Insert the close nipple through the knockouts
and secure with the locknuts.

Info: It may take three locknuts on the close nipple to anchor the controller to the
enclosure. An additional locknut may be required between the enclosure and the
controller to act as a spacer. Also, a standard 1” plastic bushing should be used on the
nipple ends to protect the wire insulation as it enters/exits the nipple.

Figure A1-2, Charge Controller Bracket Mounting Holes