Figure 3-37, AC Voltage Checks - MPSL-60S Models

Inverter (AC)

Output

Terminals

240V*

AC Input

Terminals

AC

Breakers

AC Output

Terminals

120V

120V*

.

0V

120V

.

0V

120V

120V*

240V*

.

0V

120V*

240V*

INV

IN

INV

BYP

AC

OUT

*LEG 2 / HOT 2 voltages will

not be available unless a

second MS4024 inverter is

connected in series.

OFF

Operation

BYPASS (with AC in)

Operation

NORMAL

Operation

AC BREAKERS OPERATION

INV BYP

= ON

AC OUT

= OFF

INV BYP

= OFF

AC OUT

= ON

INV BYP

= OFF

AC OUT

= OFF

INV

IN =

OFF

INV

IN =

ON

INV

IN =

ON